Using fragrances and herbs
If you wish, you can put fragrances or dried herbs into the ceramic bowl. Observe
the following points:
● Do not put fragrances directly into the evaporator tank.
● Carefully fill the ceramic bowl, so the fragrances do not drip into the evapora-
tor tank through the holes in the ceramic bowl.
● Follow the manufacturer's instructions on the packaging of the herbs and
fragrances.

7. Maintenance

7.1. Extended periods of non-use

Moisture can accumulate in the heating rods in humid ambient conditions or
during long periods of non-use. This is a physical process and not a manufactur-
ing fault. Accumulation of moisture in the heating rods can lead to the FI circuit
breaker being triggered. In this case, contact an electrician to correct the fault
(see chapter 9. Problem-solving by the installer).
Heat the sauna heater for approximately 15 minutes every 5 to 6 weeks.
This prevents moisture from building up on the heating rods during ex-
tended periods of non-use.

7.2. Cleaning the sauna heater

Make sure that the ventilation openings are free of lint and dust. This prevents
the air circulation in the sauna heater from being restricted and prevents the
device from overheating.