15. Power port
Before first time use
Attention:
When using the appliance for the first time, it is necessary to add the oil as supplied.
Periodically check and maintain suitable oil levels and oil quality within the appliance.
Failure to keep oil levels maintained will result in damage to the machine and will void any
warranty or damages claim.
•
Remove the appliance from the packaging. Make
sure that all protective plastic film and coatings are
thoroughly removed from all surfaces.
•
Wipe the chamber interior with a dry soft cloth.
Adding the pump oil
•
Open the oil silicone cover on the rear.
•
Remove the screw cap of the oil filling port.
•
Adding oil until the oil level is between 1/2~3/4 of
the full capacity, which can be seen from the oil
inspection window.
•
Tighten the screw cap and reinstall the silicone cover.
Oil maintenance
The below is a guide on how to regularly check and maintain oil levels and quality. This is to prolong the
lifetime of the machine and ensure optimum performance.
To add oil when:
•
Using for the first time.
•
Using the unit for 25 hours or 3000 times from the first time.
•
Oil level below the 1/2 capacity.
HT497_ML_A5_v1_20240807.indb 5
16. Oil draining port
EN
18. Oil silicon cover
17. Oil inspection window
2024/8/7 19:14:12
5