Job memories and reminders
Can be accessed via the «JOB» icon on the main screen.
The settings in use are automatically saved and remembered the next time you turn on the machine.
In addition to the current settings, it is possible to save and remember so-called «JOB» settings.
There are 500 JOBS for the MIG/MAG process. Data storage is based on the current process settings, the current settings
and the user profile.
Job
This JOB mode enables JOBs to be created, saved, remembered and deleted.
Quick-Load
– Recall JOBs from the trigger when not welding.
Quick Load is a non-welding JOB recall mode (20 max) and only possible in MIG-MAG process.
From a list of previously created JOBs, JOB recalls are done by short trigger presses. All trigger modes and welding
modes are supported.
Error codes
The following table shows a non-exhaustive list of messages and error codes that may appear.
Carry out these checks and controls before contacting an authorised JBDC technician.
If the user needs to open the product, they must turn off the power supply by unplugging the electrical plug and waiting two minutes
for safety.
Error codes
OVER VOLTAGE FAULT
001
Check the electrical installation
UNDERVOLTAGE FAULT
002
Check the electrical installation
005
Earth current fault.
GENERATOR
010
Thermal protection
Fan
011
Fan fault
TRIGGER
012
The trigger is pressed.
MOTOR
015
Unable to reach the required speed
If overloaded, please check your settings.
019
Release the trigger to clear
Welding start problem
020
Please check your welding parameters
Press and release the trigger to clear.
Messages
Solutions
Have your electrical installation checked by an authorised person.
There is a stray current. Check the wiring of the welding accessory
(torch, earth clamp, electrode holder, etc.)
Wait a few minutes for the power source to cool down.
Ensure that the recommended duty cycle for the welding current used
is not exceeded. Thermal protection Ensure that the air inlets and
outlets are not obstructed.
Fan Switch off the power supply by unplugging the electrical plug and
check the fan. Ensure that the fan is not blocked.
Remove the torch and check that the message is still applicable
Check that the «Gas purge / Wire feed» switch is not obstructed or
stuck.
Check that the MIG/MAG torch trigger is not obstructed or stuck.
Check the pressure settings of the motorised reel rollers.
Check that the filler wire is not blocked in the torch sheath.
If it is Impossible to reach the requested speed, calibrate the speed of
the motorised wire reels (Menu «Calibration»).
Check the power source's settings and the machine's installation (filler
wire, rollers, etc.)
If the problem persists, carry out an update.
Check the power source's settings and the machine's installation (filler
wire, rollers, etc.)
If the problem persists, carry out an update.