Télécharger Imprimer la page

Neptun NTP-E 110 Automatic Instructions D'origine page 18

Publicité

such a collection point, you should ask in your
local council offi ces.
10. Storage
Store the equipment and accessories in a dark
and dry place at above freezing temperature. The
ideal storage temperature is between 5 and 30
°C. Store the electric tool in its original packaging.
11. Troubleshooting guide
Faults
The equipment
does not start
The equipment
does not pump
The equipment
does not cut out
Insuffi cient pumping
rate
The equipment swit-
ches off after briefl y
running
Anl_NTP-E_110_Automatic_SPK7.indb 18
Anl_NTP-E_110_Automatic_SPK7.indb 18
GB
Cause
- Power supply not connected
- Intake sieve clogged
- Discharge hose kinked
- There is a leak on the delivery side
- Intake sieve clogged
- Performance reduced due to heavi-
ly contaminated and abrasive water
impurities
- Motor circuit-breaker switches the
equipment off due to excessive wa-
ter contamination
- Water temperature too high; motor
circuit-breaker switches the equip-
ment off
- 18 -
Remedy
- Check power supply
- Clean intake sieve with water jet
- Unkink the hose
- Clean the delivery side
- Clean intake sieve
- Clean equipment and replace wear
parts
- Unplug power plug and clean
equipment and shaft
- Ensure that maximum permissible
water temperature (35 °C) is not
exceeded
26.10.2020 07:48:16
26.10.2020 07:48:16

Publicité

loading

Ce manuel est également adapté pour:

41.714.34