3.5 Accessories
Accessories
Programming key card
Clearing key card
User key
Macros
4. Mounting and installation
The installation instructions for the system components can be found in separate documents.
They can be obtained under the respective catalogue number at: www.hafele.com
Please pay attention to the following points when installing the system:
W
ARNING
Risk of life-threatening electric shock during assembly and installation work
when the power plug is plugged in
The system must be currentless for the entire assembly and installation process.
• Never connect the power plug to the socket during assembly and installation.
The environmental conditions in the place of installation – for example, magnetic fields
or metal materials – may impair the functionality of the system.
• Ensure that the system is installed in a suitable location.
• Set up a sample installation in the chosen location and test it out prior to carrying
out the final installation.
Do not connect the power plug once the assembly and installation work is complete.
Connecting the system to the power supply launches the commissioning process
automatically.
• Read chapter 5. Start-up, page 51 before connecting the power plug for the first
time.
Description
• Card for granting access authorisations
• Card for clearing access authorisations
• Electronic key
• Different designs are possible:
key card, key tag, key fob, key wristband
• On request
3.1 System overview, page 43
49