Télécharger Imprimer la page

American Standard RAPIDWAY Serie Instructions D'installation page 2

Publicité

2
FIXTURE MOUNTING
Fixture studs should project
58mm (2-1/4") from face of finished wall.
3
Place back-up nuts on both bottom bolts, and
the top left-hand bolt only.
Adjust the two lower back-up nuts so that front
face of nuts and washers are positioned to allow
a minimum 1/16" (2mm) gap between fixture and
wall surface.
Adjust waste horn to project 7mm (5/16") from
finished wall.
CLOSET
CARRIER
SYSTEM
5
NOTE: Bearing nuts and washers must be set to take full loading from the fixture allowing 1/16" (2mm) clearance between fixture and wall.
Follow support manufacturer's recommended setting of closet outlet connection.
Place felt or neoprene gasket (wax ring not recommended) on closet outlet.
When the fixture is installed, closet outlet gasket must be compressed sufficiently to assure a gas and watertight seal.
The following steps require a helper:
Install bowl on support using cap nuts and fiber washers with the back-up nuts and washers.
DO NOT APPLY TOP RIGHT FIBER WASHER AND CAP NUT UNTIL OTHER CAP NUTS HAVE BEEN FIRMLY TIGHTENED USING A WRENCH.
Install top right cap nut with fiber washer and run up hand tight. Wrench tighten approximately 1/4 turn.
Apply sealant to gap between bowl and finished wall. Remove excess sealant.
For warranty information please follow this link:
https://www.americanstandard-us.com/support/warranty
In the United States:
American Standard Brands
865 Centennial Ave.
Piscataway, NJ 08854
Attention: Director of Customer Care
For residents of the United States, warranty
information may also be obtained by calling the
following toll free number: (855) 815-0004
www.americanstandard.com
FINISHED WALL
58mm
(2-1/4")
(3) STUDS
SIDE VIEW
4
FINISHED WALL
(3) NUTS
WASTE HORN
7mm (5/16" )
In Canada:
LIXIL Canada Inc.
5900 Avebury Rd.
Mississauga, Ontario
Canada L5R 3M3
Toll Free: (855) 836-9615
www.americanstandard.ca
- 2 -
Using a level, adjust the top left back-up nut so that it is in
the same vertical plane as the lower left back-up nut.
In Mexico:
American Standard B&K Mexico
S. de R.L. de C.V.
Via Morelos #330
Col. Santa Clara
Ecatepec 55540 Edo. Mexico
Toll Free: 800-839-1200
www.americanstandard.com.mx
FRONT VIEW
FINISHED WALL
2mm (1/16")
(IRREGULAR
WALL SURFACE)
LEVEL
7302213-10 0 Rev. 1 ( 8/ 2 2)

Publicité