Gas conversions (from Natural gas to L.P.gas; or from L.P.
gas to Natural gas} must be done by a qualified installer.
Fire Hazard
Shut off gas supply line valve.
Make all conversions before turning
gas supply
valve back on.
Failure to follow these instructions can result in
explosion, fire or other injury.
L.R gas conversion
= Complete installation sections A-C (Pages 7-8)
before converting cooktop to L.R gas. Check that main gas
supply line has been shut off and the power supply cord is
disconnected.
regulator
-_ .....
....
\_
......
pressure
_lastic
regulator ever
plastic
cover
--washer
--
Nat. gas
L.P. gas
DO NOT REMOVE THE PRESSURE REGULATOR.
[] Pressure regulator: Remove storage drawer and locate
pressure regulator at back of range. Remove plastic cover.
Turn cap marked "N" on front of pressure regulator counter-
clockwise with a wrench to remove. Do Not disturb or
remove the spring beneath the cap.Turn the cap over and
reinstall cap on regulator so that the letters "L.F' are visible.
Replace plastic cover over cap.
Page 12
reinstall
one of the
[] Surface Burners:
orifice
screws
spud
Remove burner caps. Use
\
_k___ s,,arkelectrode
_..,,.
_
.
orifice
\
°-
_"
a rnnHps or L_uaarex
spud
._
/
screwdriver to remove
holder_
_
_/-,_
the two screws holding the
___._
burner head down. Lift the
\__
burner head off the cooktop
_
fX
to uncover the orifice spud
range cooktop
holder.The orifice spud is recessed in the holder.
Note: Reinstall one of the screws through the range cooktop
to hold orifice spud holder in place while removing and
replacing orifice spuds.
Locate the L.R gas orifice spuds in literature
package. Orifice spuds are stamped with a
number and marked with two color dots and has
a groove,
s/! 6"
nut driver
L,P.gas
orifice spud
orifice
spud.
Replace orifice
__)
spud with the
_/_
number listed
,((
_
_.
in chart.
/_-_j)
_orifice
f
number
burner
/
assembly
L.R Gas
Surface
Propane
Orifice
Color
burner
Rate(BTU/hr)
Number
Marking
Left rear
8,000
L80
Green/Lt. Blue
Left front
11,000
L99
Green/Yellow
Right front
8,000
L80
Green/Lt. Blue
Right rear
5,000
L65
Green/Brown
A brass orifice spud is located in the center of each burner
throat about 2" below the cooktop. Apply masking tape to
the end of a 5/16" nut driver to fit snugly over the orifice
spud. Press driver down onto the spud of the left front
burner and remove by turning spud counter-clockwise and
lifting it out. Replace the Natural gas spud with the
appropriate L.R gas spud shown in the table.
Continue to replace the remaining orifice spuds, one at a
time. Place the Natural gas spuds in plastic parts bag for
future use and keep with literature package. Replace burner
caps using both screws, and burner grates.
groove
pin
hood
L.R gas
Natural
gas
decrease
increase gas
gas
increase
decrease
flame
size
flame
size
pro-set
at factor_
for Natural
gas
orifice hood
,, Oven burner: Use 1/2" combination wrench to turn the
orifice hood down snug onto pin (approximately 2 to 2-1/2
turns). DO NOT OVERTIGHTEN.The burner flame cannot be