The attachments scrape
against the bowl
The attachments do not
touch the bottom of the
mixing bowl
The device moves when
it is on
SECTION 6: ENVIRONMENT
At the end of its life, this device must not be disposed of with normal household waste, but
must be handed over to a special collection point for the recycling of electrical and electronic
devices. The symbol on the device, in the operating instructions and on the packaging draws
your attention to this. The materials used in the device can be recycled. By recycling used
household appliances, you make an important contribution to protecting our environment.
Ask your local authorities for the collection point.
SECTION 7: WARRANTY
Thank you for purchasing our product, which is made to meet high quality standards. The
manufacturer's warranty covers the product against manufacturing defects for a period of 2
years from the date of purchase.
DE
Vielen Dank, dass Sie sich für eines unserer Fentic-Produkte entschieden haben! Für den
Kundensupport wenden Sie sich bitte an unsere E-Mail-Adresse: info@fentic.eu.
ABSCHNITT 1: WICHTIGE SICHERHEITSMASSNAHMEN
Dieses Gerät enthält elektrische Anschlüsse und bewegliche Teile, die eine Gefahr
für den Benutzer darstellen können. Um das Risiko schwerer Verletzungen bei der
Verwendung Ihres Geräts zu verringern, sollten die folgenden grundlegenden
Sicherheitsvorkehrungen befolgt werden.
LESEN UND BEWAHREN SIE ALLE ANWEISUNGEN, SICHERHEITSVORSCHRIFTEN UND WARNUNGEN
AUF, BEVOR SIE DIESES GERÄT VERWENDEN
Die Nichtbeachtung der Sicherheitsregeln und Anweisungen für eine sichere Verwendung kann zu
schweren Verletzungen führen und Ihre Garantie ungültig machen.
The mixing bowl is placed
incorrectly
The attachment is placed
incorrectly
To prevent scratches, the
attachments do not touch
the bottom of the mixing
bowl
The non-slip feet are not
firmly attached
The device is not on a stable
surface
The device is on the highest
setting
Place the mixing bowl correctly in the
housing
Place the attachment correctly at the
attachment point
This is a normal phenomenon
Check that the anti-slip feet are firmly
attached
Place the device on a stable and firm
surface
This is a normal phenomenon
32