4. Technical data

Power supply:
Motor rating in kW:
Operating mode
Compressor speed in rpm:
Operating pressure in bar:
Pressure vessel volume in litre:
Theoretical intake rate in l/min.:
Sound power level L
in dB:
WA
K
uncertainty
WA
Sound pressure level L
in dB:
pA
K
uncertainty
pA
Protection type:
Machine weight in kg:
Operating mode S3 - 25% - 10min: S3 = Intermittent
mode without influencing the starting process. This
means that during a period of 10 min the max.
operating time is 25% (2.5 min).
5. Points to note when setting up the
compressor
Examine the machine for signs of transit
damage. Report any damage immediately to the
company which delivered the compressor.
The compressor should be set up near the
working consumer.
Avoid long air lines and long supply lines
(extensions).
Make sure the intake air is dry and dust-free.
Do not set up the compressor in damp or wet
rooms.
The compressor may only be used in suitable
rooms (with good ventilation and an ambient
temperature from +5°C to +40°C). There must be
no dust, acids, vapors, explosive gases or
inflammable gases in the room.
The compressor is designed to be used in dry
rooms. It is prohibited to use the compressor in
areas where work is conducted with sprayed
water.
11.08.2011
7:32 Uhr

6. Assembly and starting

Important!
230 ~ 50 Hz
You must fully assemble the appliance before
using it for the first time.
1.1
S3 25% 10 min
3550
6.1 Fitting the wheels (3)
Fit the supplied wheels as shown in Fig. 3.
8
24
6.2 Fitting the supporting foot (4)
Fit the supplied rubber stopper as shown in Fig. 4.
176
37
6.3 Voltage
2 dB
The compressor is equipped with a mains cable with
shock-proof plug. This can be connected to any
75
230V ~ 50Hz shock-proof socket which is protected
2 dB
by a 16 A fuse. Before you use the machine, make
IP 20
sure that the mains voltage complies with the
20
specifications on the rating plate. Long supply
cables, extensions, cable reels etc. cause a drop in
voltage and can impede motor start-up. In the case
of low temperatures below +5°C, motor start-up is
jeopardized as a result of stiffness.
6.4 On/Off switch (8)
To switch on the equipment set the On/Off switch (8)
to position 1.
Move the On/Off switch (8) to position 0 to switch off
the equipment.
6.5 Adjusting the pressure: (Fig. 1)
You can adjust the pressure on the pressure
gauge (6) using the pressure regulator (7).
The set pressure can be taken from the quick-
lock coupling (5).

6.6 Setting the pressure switch

The pressure switch is set at the factory.
Switch-on pressure 6 bar
Switch-off pressure 8 bar
Seite 13
GB