in a safe place for future use.
2. Layout and items supplied
2.1 Layout (Fig. 1)
1. Pressure connector
2. Water drain screw
3. Pressure gauge
4. Suction connector
5. Water fi ller screw
6. Pressure switch
2.2 Items supplied
Please check that the article is complete as
specifi ed in the scope of delivery. If parts are
missing, please contact our service center or the
sales outlet where you made your purchase at
the latest within 5 working days after purchasing
the product and upon presentation of a valid bill
of purchase. Also, refer to the warranty table in
the service information at the end of the operating
instructions.
•
Open the packaging and take out the equip-
ment with care.
•
Remove the packaging material and any
packaging and/or transportation braces (if
available).
•
Check to see if all items are supplied.
•
Inspect the equipment and accessories for
transport damage.
•
If possible, please keep the packaging until
the end of the guarantee period.
Danger!
The equipment and packaging material are
not toys. Do not let children play with plastic
bags, foils or small parts. There is a danger of
swallowing or suff ocating!
•
Original operating instructions
3. Proper use
Applications:
•
Irrigation and watering of green areas, vege-
table beds and gardens.
•
Operation of lawn sprinklers.
•
Drawing of water (with pre-filter) from ponds,
streams, rain barrels, rainwater cisterns and
wells.
•
Supplying water to the house.
Anl_GC-WW_6036_SPK1.indb 14
Anl_GC-WW_6036_SPK1.indb 14
GB
Transport media:
•
For the pumping of clear water (fresh water),
rainwater or light suds/service water.
•
The maximum temperature of the fluid must
not exceed +35°C if the equipment is opera-
ted permanently.
•
Do not use the equipment to pump inflamma-
ble, gassing or explosive fluids.
•
The pumping of aggressive liquids (acids, al-
kalis, silo seepage etc.) as well as liquids with
abrasive substances (sand) must likewise be
avoided.
The equipment is to be used only for its prescri-
bed purpose. Any other use is deemed to be a
case of misuse. The user / operator and not the
manufacturer will be liable for any damage or inju-
ries of any kind caused as a result of this.
Please note that our equipment has not been de-
signed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
4. Technical data
Mains connection ...........................230V ~ 50 Hz
Power rating .............................................. 600 W
Max. pumping rate ..................................3600 l/h
Max. delivery head ...................................... 40 m
Max. delivery pressure .................0.4 MPa (4 bar)
Max. suction height ....................................... 8 m
Pressure and suction connector ..........................
approx. 33,3 mm (R1 IG)
Max. water temperature ............................. 35 °C
Tank capacity .................................................20 l
Cut-in pressure approx. ..........0.15 MPa (1.5 bar)
Cut-out pressure approx. .............0.3 MPa (3 bar)
sound power level ............................... 77,8 dB(A)
Uncertainty ................................................ 3.6 dB
- 14 -
06.04.2017 11:49:49
06.04.2017 11:49:49