Cleaning and Disinfection: File Holder Adapter
NOTE: Do not spray the File Holder Adapter with a
liquid disinfectant.
1. Clean the surfaces of the file holder adapter with a tissue
containing isopropyl alcohol (e.g., CaviWipes).
• Wipe the surface of the file holder adapter at least twice
in one minute.
• Clean the surface of the file holder adapter thoroughly to
avoid leaving any residue of contamination.
2. Dry the file holder adapter with a soft cloth, and dry at room
temperature for at least 30 minutes.
STORAGE AND DISPOSAL
1
Storage:
After sterilization, place the pouches containing the devices in a
dry and dark place such as a closed cupboard or a drawer.
• Follow the instructions provided by the pouch manufacturer
regarding storage conditions and maximum allowed time
in storage.
2
Disposal
• For proper disposal always follow local and regional laws
(i.e. The Waste Electrical and Electronic Equipment - WEEE).
TROUBLESHOOTING GUIDE AND
TECHNICAL SUPPORT
If a problem occurs with the device, refer to the guide below. If
this guide does not resolve the problem, contact Customer Care
at 1-800-537-7123 (Available from 6:00am to 4:00pm PST).
Outside of these hours, email us at KerrCustCare@kavokerr.
com. Alternatively, contact the dealer or Kerr Endodontics sales
representative.
Problem
The power does
The battery
not turn on.
is dead.
The Apex
Connect unit
is charging.
The Apex
The battery
Connect Unit
is dead.
turns off
during use.
When
Either the File
connecting the
Holder B or File
File Holder B
Holder Adapter
or File Holder
is faulty.
Adapter, the
screen
automatically
turns off.
No alarm sounds. The alert sound
volume is set
to '0' .
The
The probe cord
measurements
is not properly
are not displayed.
connected.
Even though the
The root canal is
file has reached
completely dry.
the APEX, the
measured value
is not displayed.
9
Cause
Solution
Charge the battery before use.
If the problem persists, please
contact customer care
The Apex Connect Unit is
designed not to operate while
charging. Disconnect the
AC/DC Adapter from the device
and press the power button
Charge the battery before use.
Switch off and restart the device
after replacing with the new File
Holder B or File Holder Adapter.
Refer to "User Environment
Settings" and adjust the
alarm volume.
Refer to "INITIAL SET-UP" and
install the probe cord.
Add saline solution to the
root canal.
Problem
Measurement
is not working
properly.
Er will flash
on the
measurement
screen.
SPECIFICATIONS
1
General Specifications:
Protection from electric shock
Degree of Protection (IEC 60529)
2
Device specifications:
Apex
[
].
Connect
Unit
AC/DC
Adapter
3
Environmental Specifications:
Operation
Storage and
transportation
WARRANTY
Kerr Endodontics warrants the system (excluding batteries) to
be free from defects in materials or workmanship for period
of 3 years from the original date of purchase. The batteries are
warrantied for a period of 6 months from the original date of
purchase.
Cause
Foreign
Measure after removing foreign
substances such
objects from the mouth.
as washing
liquid have
accumulated in
the mouth.
There is a metal
Make sure that the metal
restoration on
restoration is not connected
the tooth.
to the root canal or the file, as
errors may occur if the metal
restoration is connected to the
root canal or contacts the file.
There is necrotic
If necrotic dentin and inorganic
dentin or tissue
debris in the root canal are not
and inorganic
removed, errors may occur, so
debris in the
please start the measurement
root canal.
with a thick file to a thin file.
This is a multi-
Check with a radiograph if there
rooted canal
are any cracks in the teeth and
tooth.
then re-measure
Calibration
Disconnect the probe cord from
has not been
the Apex Connect Unit. Restart
executed.
the Apex Connect Unit and
reattach the probe cord to the
device. If problem persists, please
contact Kerr Customer Care.
Item
Internal powered ME equipment
Applied part
Lip hook, File holder A,
File holder B, File holder Adapter
Battery
Lithium-ion battery
Item
Rated input
3.6 V / 1900 mAh (Lithium-ion
Dimensions
Weight
184 g (including battery)
Operation mode
Continuous operation
Accuracy
Input voltage
100–240 V, 50–60 Hz
Output voltage
Output current
Item
Temperature
Humidity
Atmosphere pressure
Temperature
Humidity
Atmosphere pressure
Solution
Description
IPX0
Description
battery)
90 X 75.4 X 73.6 mm
±0.5 mm
9 V DC
2.0 A
Description
10–35°C (50–95°F)
30–75%
700–1060 hPa
-20–60°C (-4–140°F)
5–90%
700–1060 hPa

Publicité

loading