INSTALLATION DIAGRAM
A
Ind.
A
Explosive area :
Area 1 (Z1) or Area 2 (Z2) : spray booth
B
Non explosive area
The 1 m / 39.37" distance indicated in this diagram is given for information purposes
only and hold harmless to Sames.
The exact delimitation of the zones is the express responsibility of the user,
depending on the materials used, the environment and the conditions of use.
The 1 m / 39.37" distance can be modified if the analysis conducted by the user
requires it.
NB: Choose the appropriate pump to ensure that the working pressure supplied is suitable for the
selected gun.
SAMES KREMLIN
B
1m
1
Description
- 6 -
Z2
Z1
2
3
Ind.
1
Pump
2
Gun
3
Conductive Airless hose
N° : 578.017.120-UK-2403
1m
Z2
Description