6. Align anti-tip bracket holes with holes in floor. Fasten anti-tip
bracket with screws provided.
Depending on the thickness of your flooring, longer screws
may be necessary to anchor the bracket to the subfloor.
Longer screws are available from your local hardware store.
Power Supply Cord
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use a new 40 amp power supply cord.
Plug into a grounded outlet.
Failure to follow these instructions can result in death,
fire, or electrical shock.
1. Disconnect power.
2. Remove the terminal block cover screws located on the back
of the range. Pull cover down and toward you to remove
cover.
A. Hold-down screws
B. Terminal block cover
All manuals and user guides at all-guides.com
Electrical Connection - U.S.A. Only
A
B
7. Move range close enough to opening to allow for electrical
connections to be made. Remove cardboard or hardboard
from under range.
8. Make electrical connections as described in the "Electrical
Connection" section.
9. Move range into its final location, making sure rear leveling
leg slides into anti-tip bracket.
10. Continue installing your range using the following installation
instructions.
Direct Wire
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper or 6 gauge aluminum wire.
Electrically ground range.
Failure to follow these instructions can result in death,
fire, or electrical shock.
3. Remove plastic tag holding three 10-32 hex nuts from the
middle post of the terminal block.
4. Add strain relief.
Style 1: Power supply cord strain relief
Remove the knockout for the 40-amp supply cord.
9