Télécharger Imprimer la page

Faber INPR30SSIB Instructions D'installation page 6

Publicité

Les langues disponibles

Les langues disponibles

IT IS HIGHLY RECOMMENDED THAT PROFESSIONAL STYLE COOKING ALWAYS BE VENTED TO THE OUTSIDE. For recirculating
installations (FIGURE 1), Charcoal Filters are necessary. Remove all grease filters and set aside. Attach one charcoal filter to each end
of the blower. Each charcoal filter attaches to the grid on the side of the blower. Rotate the filter clockwise to install and counterclockwise
to remove (FIGURE 1A). Replace all grease filters. Recirculating installations also require some duct work to divert the air out of the top or
face of the cabinet or custom hood. The duct work must not terminate inside the cabinet or custom hood.
cabinet
or
duct
work
custom
hood
inca pro 30
PLAN YOUR DUCTWORK
To ensure that the blower performs to its highest
possible capacity, duct work should be as short
and straight as possilbe.
For satisfactory performance the duct run
should not exceed 50 equivalent feet if ducted
using the required minimum 6" round duct.
Calculate the length of the ductwork by adding
the equivalent feet in FIGURE 2 for each piece
of duct in the system An example is given in
FIGURE 3.
45˚ Elbow
90˚ Elbow
90˚ Flat Elbow
Wall Cap
FIGURE 2
9 Feet Straight Duct
2 - 90˚ Elbows
Wall Cap
Total System
FIGURE 3
For best results, use no more than three 90°
elbows. Make sure that there is a minimum of
24" of straight duct between elbows if more
than one is used. Do not install two elbows
together. If you must elbow right away, do it
as far away from the hood's exhaust opening
as possible.
RECIRCULATING INSTALLATIONS
ceiling
cabinet
custom
hood
1. Disconnect and move freestanding range from cabinet opening to provide easier access
to upper cabinet or custom hood. Put a thick, protective covering over cooktop, set-in range
or countertop to protect from damage or dirt.
2. Determine and clearly mark with a pencil the center line on the cabinet or custom hood
where the rangehood will be installed.
3. Determine and make all necessary cuts in the wall and/or ceiling for the ductwork. Install
the ductwork before the rangehood.
4. Determine the proper location for the Power Supply Cable. Use a 1
this hole. Install the cable. Use caulking to seal around the hole. DO NOT turn on the
power until installation is complete.
5. Make the cut-out opening where the rangehood will be installed (FIGURE 4).
3.0 feet
5.0 feet
12.0 feet
0.0 feet
9.0 feet
10.0 feet
0.0 feet
19.0 feet
or
duct
work
inca pro 30
FIGURE 1
ceiling
FIGURE 1A
MAKE YOUR CUT-OUTS
28 7/8"
CUT-OUT
FIGURE 4
Drill Bit to make
1/4"
Version 09/12 - Page 6

Publicité

loading

Ce manuel est également adapté pour:

Inca pro 30