Error
Possible cause
RUN LED flashes green slowly Communication expected.
LED ERR illuminates red
Serious network error
IP address assigned twice
No DHCP service activated
Network timeout: No cyclical
data received for more than
30 s.
LED ERR flashes red
System error
LED L/A 1 or LED L/A 2 illumi-
No data exchange with the
nates green and flashes yel-
bus coupler.
low
Bus coupler has not been con-
figured in the control.
LED L/A 1 or LED L/A 2 is off
No connection to network
participant.
Connecting cable damaged.
Network participant dam-
aged.
Product damaged.
14 Technical data
This section contains an excerpt of the most important technical data. Further
technical data can be found on the product page in the Emerson store.
General
Dimensions
Weight
Material
Degree of contamination
Relative humidity
Ambient temperature for storage
min. ... max.
Ambient temperature during operation
min. ... max.
Max. number of valves
Max. height above sea level
Vibration resistance for EN 60068-2-6
wall mounting
Shock resistance for EN 60068-2-27 wall
mounting
Electrics
Degree of protection according to
EN 60529 / IEC 60529
Supply voltage
Valve supply voltage
Nominal current
Power supply connection type
Current consumption of the electron-
ics
Permissible ripple
Standards and directives complied with
Standard / directive Description
EMC directive
Electromagnetic compatibility of electric products and electronic
2014/30/EU
products
EN 60204-1
Safety of machinery – Electrical equipment of machines, Part 1: Gen-
eral requirements
EN 61000-6-2
Electromagnetic compatibility (EMC); part 6-2: Generic standards –
interference immunity for industrial environments
EN 61000-6-3
Electromagnetic compatibility (EMC); part 6-3: Generic standards –
Emission standard for equipment in residential environments
AVENTICS™ Modbus/TCP | 570092-BAL-AB | English
Remedy
Initiate communication at
PLC.
Check network settings.
Change IP address.
Restart DHCP service.
1. Check network connec-
tion.
2. Check cyclical operation
of PLC.
Check connections and ports.
Connect network section with
the control.
Bus coupler configured in the
control.
Connect fieldbus connection
X7E1 or X7E2 to network par-
ticipant.
Replace connecting cable.
Replace network participant.
Replace product.
Specifications
45 mm x 97.2 mm x 27.25 mm
0.089 kg
Fiberglass reinforced polyamide
2
95 %, non-condensing
-25 ... 80 °C
-10 ... 50 °C
24 (48 coils)
2000 m
±0.35 mm displacement at 10 Hz ... 60 Hz,
5 g acceleration at 60 Hz ... 150 Hz
30 g with 18 ms duration,
3 shocks each direction
Specifications
IP65 when assembled
24 V DC ±25 %
24 V DC ±10 %
3 A
M12 A-coded, 4 pin or 5 pin
0.2 A
5 %
Communication interface
Communications protocol
Connections
Modbus/TCP
Max. output data volume
Max. input data volume
15 Spare parts
Information on spare parts can be found on the product page in the Emerson
store.
16 Accessories
Information on accessories can be found on the product page in the Emerson
store.
Description
Plug connector, CN2 series, male, M12x1, 4-pin, D-
coded, 180° straight cable outlet, for the fieldbus con-
nection X7E1/X7E2
• Max. wire cross-section: 0.14 mm² (AWG26)
• Ambient temperature: -25 °C ... 85 °C
• Nominal voltage: 48 V
Base, CN2 series, female, M12x1, 4-pin, A-coded, 180°
straight cable outlet, for the connection of the power
supply X1S
• Max. wire cross-section: 0.75 mm² (AWG19)
• Ambient temperature: -25 °C ... 90 °C
• Nominal voltage: 48 V
Base, CN2 series, female, M12x1, 4-pin, A-coded, 90°
angled cable outlet, for the connection of the power
supply X1S
• Max. wire cross-section: 0.75 mm² (AWG19)
• Ambient temperature: -25 °C ... 90 °C
• Nominal voltage: 48 V
Protective cap M12x1
Specifications
Modbus TCP
Fieldbus connection X7E1 and X7E2
• Base, female, M12, 4-pin, D-coded
I/O mode
48 bits
112 bits
Item no.
R419801401
8941054324
8941054424
1823312001
24