4. Select Node Configuration tab.
5. Set the IP address.
6. Set the subnet mask.
7. Set the gateway IP address.
8. Optional: Select the setting Quick Connect.
9. Select Update Configuration.
10.Enter password. See Name plate.
ð Product restarts.
11.If the product does not restart automatically: Separate and reconnect the
power supply.
Reading out diagnosis data
5
4
Fig. 4: Valve driver diagnosis
1 Status: Green=ok, yellow=warning,
red=connection loss
3 Status of the valve coils
5 Bus coupler
5
4
3
2
Fig. 5: Bus coupler diagnosis
1 Button for restoring factory settings
3 Diagnostic data of bit 0
5 Bus coupler
1. Select Diagnostic tab
2. Select Show Details.
Activating valves
1. Check the checkbox.
2. Enter password. See Name plate.
3. Read warning.
4. Confirm warning.
5. Monitor the valve status.
Deactivating valves
Uncheck the checkbox.
u
AVENTICS™ Modbus/TCP | 570092-BAL-AB | English
1
2
3
2 Checkboxes for activating the valve
coils
4 Valve driver
1
2 Diagnostic data of bit 1
4 Diagnostic data of the bus coupler
7.1.4 Setting parameters
Notes
• The diagnostic data can be called up cyclically.
• Diagnostic bit:
– 1: error
– 0: no error
• Length of output data: 3 words.
• Length of input data: 7 words of module diagnostic data.
• The valve system sends and receives diagnostic data and output words in the
same physical sequence. The sequence cannot be changed. Most masters of-
fer the option of assigning an alias to the data.
• After configuring the PLC, the output words are assigned. See g Table 6.
• The bus coupler parameter word is appended to the output word of the mod-
ules.
Procedure
1. Call up the IP address of the product in a browser.
2. Select the tab Modbus Mapping.
3. Adjust parameters. See
g 11.2 Parameter data
4. Select Update Configuration.
5. Ensure that the length of the input data and output data in the PLC and the
valve system is identical.
6. Establish connection to the PLC.
7. Transfer valve system data to the PLC. See the PLC documentation.
Table 4: Assignment of the bits to the output positions
Byte
Bit
Output position
Valve posi-
tion
0
0
1
1
2
2
3
4
3
5
6
4
7
2
0
9
1
2
10
3
4
11
5
6
12
7
4
0
17
1
2
18
3
4
19
5
6
20
7
Activate diagnosis mask for valve outputs:
Adjust the value 0 at the desired output position.
u
Deactivate diagnosis mask for valve outputs (default setting):
Adjust the value 1 at the desired output position.
u
Transfer valve system data to the PLC. See the PLC documentation.
u
7.1.5 Updating firmware
1. Ensure that the product is not connected to the control.
2. Call up the IP address of the product in a browser.
3. Select Firmware Update tab.
4. Confirm selection.
for parameters and examples.
Byte
Bit
Output position
Valve
Valve posi-
coil
tion
14
1
0
5
12
1
14
2
6
12
3
14
4
7
12
5
14
6
8
12
7
14
3
0
13
12
1
14
2
14
12
3
14
4
15
12
5
14
6
16
12
7
14
5
0
21
12
1
14
2
22
12
3
14
4
23
12
5
14
6
24
12
7
Valve
coil
14
12
14
12
14
12
14
12
14
12
14
12
14
12
14
12
14
12
14
12
14
12
14
12
19