1. Description Tanks
Tanks Euro V
50 mm
Model
Total capacity
Ø without insulation
Ø with insulation
Height
Height with insulation
Cold water inlet
Heat exchanger outlet
Heat exchanger inlet
Recirculation
Thermostat / Thermometer
Thermostat / Thermometer
Flange
Electrical resistance
Anode
Hot water outlet
Heat exchanger surface
Heat exchanger content
Empty weight
Technical data
- Maximum operating pressure: 10 bar exchanger.
- Maximum continuous operating temperature accumulation: 95 °C.
- Testing pressure: 15 bar.
- Inorganic enamelling (vitrification).
- Insulation: in rigid expanded polyurethane thickness 50 mm.
- Insulation coating SKY Grey PVC.
- In compliance with directive 2014/68/EU, art. 4.3.
- In compliance with DIN 4753.3 and UNI 10025.
Note: in the sanitary circuit near of the boiler must be installed a safety valve with calibration maximum = 6 bar and the expansion
vessel adapted to the volume of the sanitary system.
8
C
P
G
F
H
E
D
u.m.
ℓ
A
mm
B
mm
C
mm
mm
1"
D
mm
1"
E
mm
1"
F
mm
1/2"
G
mm
1/2"
H
mm
1/2"
I
mm
DN 180
M
mm
1"1/2
N
mm
1"1/4
O
mm
1"
P
mm
m
2
ℓ
kg
O
I
N
M
150
200
160
196
600
600
500
500
990
1215
1000
1225
220
220
300
290
620
750
695
835
385
375
775
1000
330
320
655
810
Up
765
975
0,5
0,7
3,1
5,6
70
90
GB
GB
A
B
O
300
500
273
475
600
750
500
650
1615
1705
1625
1715
220
265
290
345
890
880
1165
1170
375
440
1390
1425
320
365
955
960
1390
1415
1,2
1,8
7,9
11,4
115
155