Specifications
K 3.80 M
Connected load
Working pressure
Max. permissible pressure
Water flow rate
Sound pressure level
L
(EN60704-1)
pA
Sound power level
L
(2000/14/EG)
WA
K 4.80 M
Connected load
Working pressure
Max. permissible pressure
Water flow rate
Sound pressure level
L
(EN60704-1)
pA
Sound power level
L
(2000/14/EG)
WA
K 3.80 M / K 4.80 M
Power connection
Voltage
1~50 Hz
Mains fuse (slow-blow)
Protective class
Water connection
Max. feed temperature
Min. feed volume
Feed pressure
Performance data
Detergent flow rate
Recoil force of trigger gun
Hand-arm vibration
(ISO 5349)
Dimensions
Length
Width
Height
Weight with accessories
Subject to technical modifications!
14
English
We hereby declare that the machine described
below complies with the relevant basic safety
1,7 kW
and health requirements of the EU Directives,
11 MPa
both in its basic design and construction as well
12 MPa
as in the version put into circulation by us. This
5,8 l/min
declaration shall cease to be valid if the machine
74 dB(A)
is modified without our prior approval.
90 dB(A)
1,9 kW
12 MPa
13 MPa
6,7 l/min
77 dB(A)
92 dB(A)
220 -240 V
10 A
II
40 °C
10 l/min
0,2 - 1,2 MPa
The undersigned act on behalf and under the
power of attorney of the company management.
0,3 l/min
15 N
1,35 m/s
2
Alfred Kärcher GmbH Co. KG
310 mm
Alfred Kärcher-Str. 28 - 40
D - 71364 Winnenden
336 mm
Phone: +49 7195 14-0
860 mm
Fax: +49 7195 14-2212
10 kg
CE declaration
Product:
High-pressure cleaner
Type:
1.950-xxx
Relevant EU Directives
98/37/EC
2006/95/EC
89/336/EEC (+91/263/EEC, 92/31/EEC, 93/68/
EEC)
2000/14/EC
Applied harmonized standards
EN 60335–1
EN 60335–2–79
EN 55014–1: 2000 + A1: 2001 + A2: 2002
EN 55014–2: 1997 + A1: 2001
EN 61000–3–2: 2000 + A2: 2005
EN 61000–3–3: 1995 + A1: 2001
Applied conformity evaluation method
Appendix V
Sound power level dB(A)
K 3.80 M
Measured:
Guaranteed:
K 4.80 M
Measured:
Guaranteed:
88 dB(A)
90 dB(A)
90 dB(A)
92 dB(A)