DRYER
0
WARNING:
To prevent electric shock,
disconnect electrical power supply
to the dryer before beginning kit
installation and turn off the gas
supply.
This kit is to be used with gas dryer for
which "WE25M73" appears on rating
plate located on the upper center of
the door opening.
This kit was designed to be used
with bottle gas (tanks). The gas must
be equipped with a gas pressure
regulator that provides gas between
11 inches water column maximum to
8 inches water column minimum at
the connection to the dryer.
CONVERSION KIT PART NUMBER
234D1169G001
Contents:
Item
6
WARNING -
qualified service agency in accordance with the manufacturer's
instructions, CAN/CGA-B149-1 and CAN/CGA-B149-2 installation
codes and the requirements of the authorities having
jurisdiction. The information in these instructions must be
followed to minimize the risk of fire or explosion or to prevent
property damage, personal injury or death. The qualified
service agency is responsible for the proper installation of
this kit. The installation is not proper and complete until the
operation of the converted appliance is checked as specified in
the manufacturer's instructions supplied with the kit.
LP (Propane)
Gas Conversion Kit
CONVERSION MODEL NUMBER
Description
1
Orifice (stamped - 99L)
2
Regulator (L.P.) blocking pin
3
Conversion rating plate
4
Responsibility label
5
Conversion Record Label
6
Installation instructions
3
1
Installation Instructions
This conversion kit shall be installed by
WE25M73
WE25M73
4
2
5
234D1191P001 PUB # 31-166
1
1
1
1
1
1

Publicité

loading

Sommaire des Matières pour GE GTUP240G

  • Page 1 LP (Propane) GE Consumer & Industrial Appliances Gas Conversion Kit Installation Instructions DRYER CONVERSION KIT PART NUMBER CONVERSION MODEL NUMBER 234D1169G001 WE25M73 WARNING: Contents: To prevent electric shock, Item Description WE25M73 disconnect electrical power supply to the dryer before beginning kit Orifice (stamped - 99L)
  • Page 2 WE25M73 - CONVERSION PROCEDURE: Step 1: WARNING: Disconnect Step 14: Connect the harness to the gas valve C4 electrical power supply to laundry and the igniter C6. center Step 15: Reassemble the dryer: drum, drive belt, Step 2: WARNING: Turn off the gas supply front panel, control panel and reconnect the harness connector to the dryer control.
  • Page 3 Kit de Conversión a GE Consumer & Industrial Appliances Gas L.P. (Propano) Instrucciones de Instalación SECADORA # DE PARTE KIT DE CONVERSIÓN NÚMERO MODELO DE CONVERSION 234D1169G001 WE25M73 PRECAUCIÓN: Contents: Para evitar una descarga eléctrica, Item Descripción WE25M73 desconecte el suministro de energía eléctrica de la secadora antes de...
  • Page 4 WE25M73 - PROCEDIMIENTO DE CONVERSIÓN: Paso 1: PRECAUCIÓN: Desconecte el suministro Paso 14: Conectar nuevamente el arnés a la válvula de energía eléctrica al centro de lavado. de gas C4 y al encendedor C6. Paso 2: PRECAUCIÓN: Apague el suministro Paso 15: Reinstalar la secadora: tambor, banda, de gas marco frontal, panel de control y...
  • Page 5 Trousse de GE Consommateur & Industriel Conversion au Gaz Instructions d’installation Propane SECHEUSE CONVERSION MODEL NUMBER NUMERO PRODUIT TROUSSE DE CONVERSION 234D1169G001 WE25M73 PRÉCAUTION: Contenu: Pour prévenir un choc électrique, Article Description WE25M73 déconnecter la sécheuse de la prise de courant électrique avant d’initier Orifice (ref.
  • Page 6 WE25M73 - PROCEDURE DE CONVERSION: Etape 1: AVERTISSEMENT: Débranchez le centre Etape 13: Assemblez le bruleur C5 au support la de lavage du courant électrique valve de gaz C9, enlevé dans l’étape 8. (Schéma 2) Etape 2: AVERTISSEMENT: Fermez l’arrivée de Etape 14: Branchez le harnais à...
  • Page 7 Figure 1 Figure 4 Figura 1 Figura 4 Schéma 1 Schéma 4 C1- NEW Figure 5 Figura 5 Schéma 5 Figure 2 Figura 2 Schéma 2 Figure 6 Figura 6 Schéma 6 Figure 3 Figura 3 Schéma 3...
  • Page 8 Component Identification Componente de Identificación Identification de Composante...