For non-vented (recirculating) installations:
The charcoal filter is not washable. It should last up to 6 months
with normal use.
1. Replace metal grease filter with a charcoal filter. For
information on ordering, see the "Accessories" section.
To replace filter:
1. Remove screw from the grease filter retainer.
2. Turn the grease filter retainer to release filter.
3. Reinstall the filter by placing the back edge in the channel at
rear of hood. Push filter into place, turn the filter retainer to
secure filter to range hood.
REPLACE THE INCANDESCENT LIGHT BULB
(ESN130, EFS130S1, ERS230 MODELS)
Turn off the range hood and allow the light bulb to cool.
1. Disconnect power.
2. Squeeze the plastic lens cover and remove it from the hood.
3. Screw a new 120v 75W (maximum), A19 light bulb into
socket.
NOTE: In two lamps ERS230 models, use two 40W light bulbs
instead of 75W.
4. Replace lens cover by squeezing cover and inserting tabs
into slots.
A. Light bulb socket (A19)
5. Reconnect power.
B. Lens cover
6. If new light does not operate, make sure the lamp is inserted
correctly before calling service.
B
A
REPLACING THE HALOGEN LAMP (ENM230 &
ENM236 MODELS)
Turn off the range hood and allow the halogen lamp to cool. To
avoid damage or decreasing the life of the new bulb, do not
touch bulb with bare fingers. Replace bulb, using tissue or
wearing cotton gloves to handle bulb.
If new lamps do not operate, make sure the lamps are inserted
correctly before calling service.
1. Disconnect power.
2. Use a flat-blade screwdriver and gently pry the light cover
loose.
3. Remove the lamp and replace with a 120-volt, 40-watt
maximum, halogen lamp made for a G-9 base.
4. Replace the light cover.
5. Reconnect power.