Alternating voltage (40 – 400 Hz), overload protection 250 V, Average recording for sinus signal.
range
accuracy
vC130-1/150-1
(5 – 100% of the measuring
200 V
±(1,5% + 8)
250 V
Direct current, overload protection 1A/250V + 10 A/250 V
range
accuracy
vC130-1/150-1
200 µA*
2000 µA
±(1,3% + 2)
20 mA
200 mA
±(1,5% + 8)
10 A
±(2,5% + 10)
* only with the VC130-1
Alternating current (only with VC170-1), overload protection 1A/250V + 10 A/250 V, Average recording for sinus
signal.
range (40 - 400 hz)
400 µA
4,000 µA
40 mA
400 mA
4 A
10 A
48
resolution
range)
0.1 V
1 V
resolution
0.1 µA
1 µA
0.01 mA
0.1 mA
0.01 A
range
vC170-1
400 mV*
4,000 mV
40 V
250 V
* With the VC170-1, the 400 mV measuring range
is only available via the manual measuring range
selection.
range
vC170-1
400 µA
4,000 µA
40 mA
400 mA
4 A
10 A
accuracy
±(1.6% + 5)
±(2.0% + 8)
±(2.6% + 4)
accuracy
resolution
(5 – 100% of the measuring
range)
±(2,0% + 10)
0.1 mV
1 mV
±(1,6% + 4)
0.01 V
0.1 V
accuracy
resolution
0.1 µA
±(1,3% + 2)
1 µA
0.01 mA
±(1,6% + 2)
0.1 mA
0.01 A
±(2,0% + 10)
0.1 A
resolution
0,1 µA
1 µA
0.01 mA
0.1 mA
0.001 A
0.01 A