Output Polarity Management; Output Caller Recognition Enable; Confirm Output Activation Enable; Available Networks - Bentel Security BTEL-GT Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

     Monostable OC Outputs return to standby after the set ON Time.
     Output Polarity Management
This section is used to program the standby polarity for Open Collector outputs OC1, OC2, and OC3 (Open
Collector output OC4 is reserved and Normally Closed) as follows:
   
   
where <Output no.> is the number of the output being programmed (from
     Output Caller Recognition Enable
In this section you can link the activation of outputs with calls from certain telephone numbers in the phone
book. To activate outputs with Caller ID, program the telephone number in the section "Phone Book
Management" (see the Parameters Management section). The output is activated at "cost-free" as the
Telephone Dialler, after identifying the caller, activates the output and the caller can end the call before the
Dialler answers. To program this feature, type the following keypad sequence:
where <Output no.> is the number of the output being programmed (from
are the positions of the telephone numbers saved in the phone book (1 to 3 positions can be specified).
     To cancel the setting for an output, do not input a telephone number.
     Only outputs OC1, OC2, and OC3 can be activated by caller recognition.
     Confirm Output Activation Enable
This section is used to program the sending of a confirmation message when the output is activated. If this
option is programmed, when an output is successfully activated, the user will receive confirmation. Confirmation
takes the following form:
– a tone if output activation takes place through caller ID.
– a text message containing the same command received by the BTEL-GT if the output is activated by a
text message.
To enable or disable, type the following keypad sequence:

Available Networks

     For this test the SIM CARD should not be inserted in the SIM card slot.
This section covers testing reception at the chosen location for installation, in order to identify the operator with
the best coverage. To verify, press
begin listing the codes of the operators with reception (see the table on page 4 or consult the table at the website
http://en.wikipedia.org/wiki/Mobile Network Code) and after that the strength of the signal tested (low, medium,
good, excellent).
     During this test, the 3 GREEN LED's will flash (see the section "Status LEDs").

Management Installer Code

The factory default Installer PIN is 11111. To change it, type the following keypad sequence:
where <New PIN> is a number of 5 digits.
     The PIN's typed must be identical, and must be different from the user PIN, or you will be
asked to retype the PIN.
GSM Telephone dialler
<Output no.>
<Output no.>
   
<Output no.><Telephone Numbers>
   
<Output no.>
   
<Output no.>
. After waiting for approximately 15 seconds, a voice message will
<New PIN><Repeat New PIN>
(set as Normally Open - Factory default setting)
(set as Normally Closed)
(to Enable)
(to Disable - Factory default setting)
to
).
to
) while <Telephone Numbers>
G
35

Publicité

Table des Matières
loading

Table des Matières