Advanced Management
This section mainly describes the procedures for programming the way the inputs and outputs work, as well
as the dialler's advanced features.
Management Input Polarity
To program activation of the 4 inputs (for more information, see the section on "Connecting the device-
>Activation Polarity"), type the following keypad sequence:
where <Input no.> is the number of the input being programmed (from
positive
(factory default setting) or negative
negative polarity.
Periodic Message
In this menu one can program the periodic sending of voice message no. 8 to the number stored in the phone
book as no. 1. For further information, consult the sections "Parameters Management->Phone Book
Management" and "Parameters Management->Voice Message Management". To program this option,
type the following keypad sequence:
where <No. of days> corresponds to the number of days until a message is sent (from
disable transmission, press
Language change
In this menu you can change the language for the voice commands. To program this feature, type the
following keyboard sequence:
where <Language> corresponds to :
Set Date and Time
To program this feature, type the following keyboard sequence:
for each parameter, such as <Hour><Minutes><Day><Month><Year>, type two digits, for example, to set the
date to the third day of the month, press
After scheduling a new date, any regularly sent text messages in the system must be re-entered.
Output Management
The 4 Open Collector Outputs can be activated automatically (when pre-programmed events take place).
This menu is used to program the Outputs, their polarity (N.C. or N.O.), their status as 'Monostable' or
'Bistable', activation via caller recognition, and confirmation of the outputs activation.
Output Type Management
Open Collector Outputs OC1, OC2, and OC3 can be set as Bistable (activation and deactivation take place
through two different commands) or as Monostable (the output remains active for its ON Time, after which
it returns to standby status; Output OC4 is preset as Bistable only. To program this feature, type the following
keypad sequence:
where <Output no.> is the number of the output being programmed (from
in seconds, from
to
34
. The factory default setting is 0 (disabled).
=Italian
<Hour><Minutes><Day><Month><Year>
<Output no.>
(to set to Bistable)
<Output no.><ON Time> (to set to Monostable - factory default setting)
(factory setting: 10 seconds).
<Input no.><Polarity>
. For example
<No. of days>
<Language>
=English
=French
and for the year 2012 press
to
), while <Mode> can be
programs input no. 2 for
to
=Spanish.
.
to
) while the <ON Time> is
); to
BTEL-GT