LED flashes
Continuously
(flashes ON/OFF twice in
(500ms ON/OFF)
500ms, then OFF for 2
—
Fig. 5 - Indications of the dialers status from the Green LED's.
Once the language is selected, the voice menu for programming will become active in the language chosen.
The interface language can also be changed, either from a menu in the corresponding section or by using a
keypad sequence (see section "Advanced Management->Language change"). This also allows the
device to be programmed in one language and then operated in another one.
When the device is turned on, no voice or text messages are sent until the radio module is completely initialized.
Any input activation will be ignored. If the dialler is not capable of performing the command associated with the
activation of an input, the command will be memorized and executed when the device returns to being ready,
which allows for the handling of multiple messages due to the simultaneous activation of multiple inputs. For
optimal installation of the device, search for the operator with the best coverage.
Priority management
The BTEL-GT can send voice and text mesages. Text messages have a higher priority compared to voice
messages. If at the end of a voice message, there are text messages to be sent with the activation of another
input, the latter are sent before any other voice mesages.
IMPORTANT - Input no. 1 (L1) takes priority over the other inputs: if input no. 1 (L1) is
activated, the call cycles related to it are carried out, even if at that moment the dialler was
going through cycles linked to a different input.
For example, if an alarm takes place on input 2 and a few seconds later, an alarm occurs on input 1, the BTEL-
GT stops sending the voice message originating from input 2 and then sends the voice messages connected with
input 1. Once it has finished sending the voice messages for input 1, the BTEL-GT starts sending the voice
messages in the queue originating from input 2 once again.
When multiple inputs are activated, the alarms are placed in a queue and they are cancelled
only at the end of all the programmed actions for every input.
Event
Event taking place
Priority
Sending SMS
1 (HIGH)
message
Sending voice
2
message
To program call cycles, see the section "Parameters Management->Management options calls".
Programming sets a series of parameters needed for the BTEL-GT to work, enabling it to adapt to the
particular type of installation and use desired. The Installer menu can be accessed via the system's keypad
. A block diagram of the Installer menu is shown below.
GSM Telephone dialler
BTEL-GT dialler status indication
Intermittently
seconds)
—
OPERATING PRINCIPLES
Table of Priority Handling
When finished sending the message, the actions concerning input channel 1 will be
The call is completed, the events are placed in a queue and they will be ransmitted
PROGRAMMING
Problem with the SIM card
The dialer is initializing; flash until a GSM signal is
Action to activate input channel 1 (L1)
carried out.
at the end of input channel 1's alarm cycle.
Meaning
received
G
29