TROUBLE-SHOOTING
Problems
The appliance does
not work
The lighting inside
the chamber does
not work
The appliance works
continuously
Water collects in the
lower part of the
appliance
Possible causes
The electric circuit is
disrupted
The bulb is loose or
fused (only appliances
with bulb lightning
type)
Incorrect setting of the
adjustment knob
See. "Temperature inside
the appliance is not low
enough for description of
other possible causes
The water discharge
opening is clogged
(depending on the
model)
Internal air circulation
obstructed
Remedies
- check whether the plug is
properly inserted into the
socket
- check whether the power
cable of the appliance is not
damaged
- check whether there's
voltage in the socket, by
plugging another appliance,
e.g. a night lamp
- check whether the appliance
is switched on by setting the
thermo-stat to a position
above 0.
-fit the bulb correctly or
replace it (see section
above "Replacing the
interior light bulb)
-reset the knob to a
lower position
See. "Temperature inside
the appliance is not low
enough for description of
other possible causes
-clean the discharge
opening (see the operating
manual – chapter entitled
"Defrosting the fridge")
-place the food an
containers in such a way
as that they do not touch the
rear wall of the fridge
- 26 -