BEFORE PLUGGING IN THE UNIT TO A POWER SOURCE:
1.
Let the unit stand upright for a minimum of 2 hours. This will reduce the chance of
malfunction in the cooling system.
2.
Ensure the rubber drain plugs are securely plugged into the drain ports on the back of the
unit to prevent any possible water leaks.
3.
Ensure the exhaust hose and window kit installation has been installed properly and properly
vented.
Conduct a Power Plug Check:
1.
Press the RESET button on the power cord.
2.
Plug the cord into an electrical outlet.
3.
Press the TEST button on the power cord. The RESET button should pop up.
4.
Press the RESET button for use.
5.
Do not use the air conditioner if the test fails.
NOTE :
1.
If you turn the air conditioner off and immediately restart it, allow up to 3 minutes for the
compressor to restart cooling. In the event of a power failure, wait 3 minutes before
restarting the unit.
2.
The unit sold in the United States is preset to Fahrenheit. the unit sold in Canada is preset
to Celsius.
INSTALLATION
The air conditioner requires being vented outside so that the exhaust air can escape the room.
Do not replace or extend exhaust hose beyond its specification. This will result in decreased
efficiency of the unit and may cause the unit to shut down due to low backpressure.
The window kit can be installed either horizontally or vertically.
The window kit can be adjusted from 26.6"-47.2" (675-1200mm).
The exhaust hose can be adjusted from 9.4"-59" (240-1500mm).