SEM10 (fig. 36)
SEM10 product has been designed to be installed under the kitchen cabinet, corresponding to the
downdraft lower air outlet . This product can work only if it is used in combination with a downdraft
equipped with external motor, manufactured by the same producer.
The appliance has been designed to suck vapours and odours in an optimal and almost noiseless way
. We recommend to use the product only in FILTERING MODE and to use a constant diameter piping
of 150mm or similar sections.
We recommend to use piping without elbows, as they negatively affect the performance of the appliance.
Installation procedure: place the appliance under the downdraft , corresponding to the air outlet, as
shown in (fig. 37).
All fittings are supplied with the appliance, along with a rectangular pipe that connects the downdraft to
the SEM10 product
The appliance air outlet shall be connected to the cabinet, in such a way that the air sucked in the
kitchen can be recirculated back into the room. Piping to be connected to the SEM10 product air outlet
are not supplied with the appliance.
It is possible to direct the product air outlet according to your installation requirements, by rotating the
air outlet flange as shown in (fig. 38).
The appliance is equipped with a 1,5 meter long power cable, to be connected to the hood in the spe-
cific terminal board found inside the plastic black box (Fig. 8).
The product is supplied with a metallic joint (fig. 39) which allows to put ahead the SEM 10, as shown in
fig 40. This possibility depends strictly on the dimension of the furniture.
When the joint in fig. 39 is used, it is very important not to use the white metallic flange, but remove it
as shown in fig. 38.
With reference to the Energy Label standard and taking into account its performances, it is not neces-
sary to equip the product with any time control device.