9.
Installation example
10. Assembly of connection block
Important!
The panel thickness may be max. 25 mm.
10.1 Remove the threaded rods (a) and dispose of them.
10.2 Remove the hoses (b) and keep them.
10.3 To be kept:
b 2 hoses
c O-ring
d Seal
e Plastic disk
g 2 threaded nuts
10.4 To be disposed of:
a 2 threaded rods
f Attachment washer
10.5 Remove the stopper (h) and dispose of it.
10.6 Screw the pipes (k) into the tap.
10.7 Screw the threaded rods (i) into the tap.
10.8 Screw the hoses (b) into the connection block (l).
10.9 Turn the threaded ring (m) downwards at the connection block (approx. to tap
landing height).
10.10 Slide the connection block (l) through the tap landing from the bottom.
10.11 Place the tap (n) onto the washstand with the O-ring.
10.12 Screw a threaded nut (p) onto a threaded rod (o) and tighten.
10.13 Turn the threaded ring (m) as far upwards as it will go.
10.14 Slightly loosen the threaded nut (1-2 turns).
10.15 Align the tap.
10.16 Again turn the threaded ring (m) as far upwards as it will go.
10.17 Screw the second threaded nut (p) onto the threaded rod (o).
10.18 Tighten the threaded nuts (p).
The angle valves (s) must be provided by the customer.
10.19 Screw the connection hoses (r) onto the angle valves.
10.20 Open the angle valves.
10.21 Check the water connections for leaks.