Télécharger Imprimer la page

KWC ACLX1001 Notice De Montage Et De Mise En Service page 12

Publicité

Les langues disponibles
  • FR

Les langues disponibles

18. Replacing the solenoid valve cartridge
18.1 Close the angle valves.
18.2 Trigger the tap.
18.3 Remove the battery compartment or wall installation power pack from the sensor.
18.4 Remove the sensor (b) from the solenoid valve cartridge (a).
18.5 Loosen the solenoid valve cartridge (a), using an open-ended wrench.
Important!
The solenoid valve cartridge must be connected before the power supply is
connected.
18.6 Reassemble in reverse order.
19. Spare parts
Description
Solenoid valve cartridge. . . . . . . . . . . 2030045522
Sensor type 8. . . . . . . . . . . . . . . . . . . 2030041487
Accessories
Order No.
Remote control. . . . . . . . . . . . . . . . . . 2030036654
2-button remote control . . . . . . . . . . . 2030036849
Battery compartment . . . . . . . . . . . . . 2000109466
Plug-in power supply . . . . . . . . . . . . . 2030039823
- 12 -
Order No.

Publicité

loading

Ce manuel est également adapté pour:

Aclx100320300689852030068986