DESCRIPTION
typ
BYM device type selection
Fabrication value loading
def
(when 1 inserted fabrication values are loaded)
Type of heat unit indication
deg
( °C - °F )
Change of LIGHT WASH time
Y1
(sec)
Change of NORMAL WASH time
Y2
(sec)
Change of HEAVY WASH time
Y3
(sec)
Change of LIGHT WASH-RINSE time
d1
(sec)
Change of NORMAL WASH-RINSE time
d2
(sec)
Change of HEAVY WASH-RINSE time
d3
(sec)
Change of drain time in between wash and dry
S1
(sec)
Change of drain time after rinse (end of wash)
S2
(sec)
t1
Change of water tank temperature OF LIGHT WASH
t2
Change of water tank temperature Of NORMAL WASH
t3
Change of water tank temperature of HEAVY WASH
b1
Change of RINSE (Light Wash) boiler temperature
b2
Change of RINSE (Normal Wash) boiler temperature
b3
Change of RINSE (Heavy Wash) boiler temperature
Permission for rinse before boiler reaches its targeted heat
P1
(no wash start is required, if 0 thermo stop control)
P2
Permissible first start before tank reaches its targeted heat
Permissible start without restarting
P3
Start button in the end of wash when gate is closed
P4
Working of the heating element when the cabinet door is open
Non-hysteric values
HS
(sub interval value for re-enabling heaters)
Half-power threshold value
YG
(range of proportional control of heaters to target temperature)
t 0
Tank temperture difference value
b 0
Boiler temperture difference value
Change of DISCHARGE time (sec.)
dt
"*" Do not including +15 sec. discharge time.
Detergent time during water inlet
SdS
(sec.)
Detergent time during rising
ddS
(sec.)
At
Rinse into the cabin before washing process
When the default value is finished, the boiler heaters will be
ECO
deactive position. The boiler does not work until the device
becomes active again
BYM Service Parameters:
INTERVAL VALUE
BYM042
BYM052
042/052/102
42A/52A/10A
---
---
10H
0 - 1
0
0
C - F
C
C
30 - 300
65
60
30 - 300
95
85
30 - 300
155
145
10 - 100
15
20
10 - 100
15
25
10 - 100
15
25
1 - 10
5
5
1 - 10
5
5
30 - 99 °C
55 °C
55 °C
(86 - 210°F)
30 - 99 °C
55 °C
55 °C
(86 - 210°F)
30 - 99 °C
55 °C
55 °C
(86 - 210°F)
30 - 99 °C
85 °C
85 °C
(86 - 210°F)
30 - 99 °C
85 °C
85 °C
(86 - 210°F)
30 - 99 °C
85 °C
85 °C
(86 - 210°F)
0: Hayır
1
1
1: Evet
0: Hayır
1
1
1: Evet
0: Hayır
1
1
1: Evet
0: Hayır
1
1
1: Evet
1 - 5°C
2 °C
2 °C
(1 - 9°F)
0 - 20°C
3 °C
3 °C
(0 - 36°F)
0 - 10°C
4 °C
6 °C
(0 - 18°F)
0 - 10°C
0 °C
0°C
(0 - 18°F)
75 - 300
120*
150*
0 - 150
100
100
0 - 40
20
20
0 - 10
0
0
0 - 120
90
90
FABRICATION VALUES
BYM042N
BYM052N
BYM102
(BYM042A)
(BYM052A)
---
---
---
0
0
0
C
F
F
35
85
85
90
145
145
150
265
265
20
25
25
25
25
25
25
25
25
3
5
5
2
5
5
55 °C
140 °F
140 °F
55 °C
140 °F
140 °F
55 °C
140 °F
140 °F
85 °C
185 °F
185 °F
85 °C
185 °F
185 °F
85 °C
185 °F
185 °F
1
0
0
1
1
1
1
1
1
1
0
0
2 °C
4 °F
4 °F
3 °C
6 °F
6 °F
6 °C
6 °F
6 °F
0°C
0 °F
0 °F
165*
120*
150*
100
100
100
20
20
20
0
0
0
90
90
90
BYM102N
BYM102H
(BYM102A)
---
---
0
0
F
C
85
65
145
90
265
150
25
20
25
25
25
25
5
2
5
3
140 °F
65 °C
140 °F
65 °C
140 °F
65 °C
185 °F
92 °C
185 °F
92 °C
185 °F
92 °C
0
1
1
1
1
1
0
1
4 °F
2 °C
4 °F
2 °C
6 °F
3 °C
0 °C
0 °F
165*
165*
100
100
20
20
0
0
90
90