S19214
Supplies Required:
•
(3)
⁄
" floor anchors and bolts
3
8
•
Teflon tape and pipe sealant
•
30 PSI (2.0 bar) min/90 PSI (6.1 bar) max flow pressure
•
125 PSI (8.6 bar) max static pressure
•
Piping to ½" NPT (BSPP) water supply inlet (30–90 psi [2.0-6.1 bar])
•
Piping to 1¼" NPT drain outlet on unit (if included with unit)
•
OPTIONAL: sign-mounting hardware
Local codes may require the installation of a backflow prevention valve to complete proper installation.
Compliance with local codes is the responsibility of the installer. Valve must be tested annually to verify that it
is functioning properly. Backflow prevention valves are not included with the fixture and may be supplied by
the contractor or purchased from Bradley Corporation.
4
1/25/2024
Bradley • 215-1685 Rev. S: ECO 23-05-001A
Installation