cable. Disconnect the plug from the socket prior to setting up the
device in another location.
If the device is not in operation, always switch it off by pressing
the ON/OFF switch. Place the electrode holder on an insulated
surface and only remove the electrodes from the holder after allowing
it to cool down for 15 minutes.
Pay attention to the condition of the welding cable, electrode
holder and the earth terminal. Wear and tear of the insulation and
the live parts can lead to hazards and reduce the quality of the
welding work.
Arc welding creates sparks, molten metal parts and smoke.
Therefore ensure that: All flammable substances and/or materials
are removed from the workplace and its immediate surrounding.
Ensure the workplace is ventilated.
Do not weld on containers, vessels or tubes that contain or contained
flammable liquids or gases.
welding current circuit. The no-load voltage between the electrode
holder and earth terminal can be dangerous, there is a risk of
electric shock.
Do not store or use the device in a damp or wet environment or in
the rain. Protection rating IP21S is applicable in this case.
Protect your eyes using the appropriate protective glasses
(DIN level 9–10), which are fastened to the supplied welding mask.
Wear gloves and dry protective clothing that are free of oil and
grease to protect the skin from exposure to ultraviolet radiation of
the arc.
pipes.
Please note:
The light radiation emitted by the arc can damage eyes and cause
burns to the skin.
Arc welding creates sparks and drops of melted metal. The welded
workpiece starts to glow and remains hot for a relatively long period
of time. Therefore, do not touch the workpiece with bare hands.
Arc welding can cause vapours to be released that may be hazardous
to health. Be careful not to inhale these vapours.
Protect yourself from the harmful effects of the arc and keep people
that are not involved in the work away from the arc, maintaining a
distance of at least 2 m.