Technical data
Prod.-No.:
Designation:
Breakaway force:
(at 0° inclination to the load)
Max. load-bearing capacity:
(at 90° inclination of the load)
Max. load-bearing capacity:
(at 90° inclination of the load)
Max. load-bearing capacity:
(on round pipes at 0° inclination)
Admissible diameter of
round pipes:
Dead weight of the unit:
Storage temperature:
Operating temperature:
Markings on the magnetic clamp
Detailed descriptions for handling and operating conditions of the TMC 600R can be found on the upper side of the
magnetic clamp. This labeling must not be modified, damaged or removed. New labels must be ordered from the
manufacturer if necessary.
Laser marking incl. serial number
on the upper side of the cap
41200.R
TMC 600R Magnetic clamp
>600 kg on 10 mm S235
30% of the breakaway force
200 kg on 10 mm S235
20 - 50% of the breakaway force
50 mm - 300 mm
2.73 kg
-30°C to +60°C
-30°C to +60°C
14
>1320 lbs on 3/8" AISI CRS 1020
30% of the breakaway force
440 lbs on 3/8" AISI CRS 1020
20 - 50% of the breakaway force
1" - 12"
6.00 lbs
-22°F to +140°F
-22°F to +140°F