Télécharger Imprimer la page

ZAPTEC Pro Manuel D'installation page 16

Masquer les pouces Voir aussi pour Pro:

Publicité

Product specifications
EN
General
Parameter
Dimensions
Charging mode
Weight
Degree of protection
Mechanical strength
Pollution degree
Support for ventilation
Access
Maximum altitude
Max noise emission
Input cable cross section
Input cable diameter
Ambient operating temperature
Electrical
Parameter
Rated voltage
Rated current
Rated frequency
Overvoltage category
Protection class
Protection against electric shock
Integrated RCCB
Parameter
Residual operating current
Operating characteristics
Making and breaking capacity
Rated conditional short-circuit
current
Normative standard
Integrated circuit breaker
Parameter
Manufacturer and part number
Rated current
Curve
Nominal short-circuit
breaking capacity
Normative standard
16
Test condition
 
 
Including backplate
 
 
Installation environment
According to EN IEC 61851-1:2019,
6.3.2.2
According to EN IEC 61851-1:2019,
5.4
 
With fan running
 
 
 
Symbol
Un
In
 
 
According to EN IEC 61851-1:2019,
8.3 and HD 60364-4-41:2017
Symbol
Δ
I
n
 
Δ
Im and I
m
Δ
Inc and I
c
Symbol
 
In
 
Icn
Value
H: 392 W: 258 D: 112
Mode 3, case B
5
IP54
IK10
4
No
Restricted and non-restricted access
2000
47.5
2.5 to 10
10 to 18.5
-30 to 40
Value
230/400
32
50
III
I
Reinforced insulation as fault
protection (between phases and PE)
Value
0.03
Type B
500
10
EN 62423:2012
Value
Lovato P1 MB 3P C40
40
C
10
EN 60947-2:2017, EN 60898-1:2019
Unit
mm
 
kg
 
 
 
 
 
m
dBA
mm²
mm
°C
Unit
V
A
Hz
 
 
Unit
A
 
A
kA
Unit
 
A
 
kA

Publicité

loading

Produits Connexes pour ZAPTEC Pro