• Reactive metal dusts (such as aluminum, magnesi-
um, zinc) combined with strongly alkaline and acidic
cleaning agents
• Undiluted strong acids and alkalis.
• Organic solvents (such as gasoline, paint thinner,
acetone, heating oil).
In addition, these substances can corrode the materi-
als used on the device.
m WARNING!
This power tool generates an electromagnetic field
during operation. This field can impair active or pas-
sive medical implants under certain circumstances.
In order to prevent the risk of serious or deadly in-
juries, we recommend that persons with medical im-
plants consult with their physician and the manufactur-
er of the medical implant prior to operating the power
tool.
6. Technical data
Mains voltage
Power
Water tank capacity
Suction performance
Protection category
Protection class
Subject to technical changes!
7.
Assembly
m ATTENTION!
Prior to use, ensure that the device has been cor-
rectly and fully assembled.
Installing roller mounts (4) (fig. D)
• Turn the stainless steel container (6) upside-down
(the machine head (1) must be removed).
• Connect the castor mounts (4) into the cut-outs pro-
vided on the stainless steel container (6). (3x)
Installing the castors (fig. D)
• Press the three castors (5) into the holes of the roller
mounts (4).
20 | GB
220 - 240V~ 50/60 Hz
1300 W
20 l
20 kPa
IPX0
II
www.scheppach.com
Installing the machine head (1) (fig. A)
• Place the machine head (1) on the stainless steel
container (6). Secure the machine head (1) with the
locking hooks (8). When installing the machine head
(1), ensure that the locking hooks (8) latch into place
correctly.
Installing the HEPA filter (14) (fig. E)
• Push the protective grate (15) over the HEPA filter
(14) and place it on the bottom of the machine head
(1). (Fig. E)
• Secure the HEPA filter (14) with the knurled screw
(18).
Fit the suction hose (13) (fig. F)
• Connect the suction hose (13) to the corresponding
port, depending on the desired use, on the ash vac-
uum cleaner.
Vacuuming (fig. F)
• Connect the suction hose (13) to the suction hose
port (3). To do so, slide the end of the suction hose
(13) with the two nipples into the suction hose port
(3).
• Insert the two nipples into the recesses. In the end
position, turn the suction hose (13) in a clockwise
direction.
Blowing (fig. G)
• Connect the suction hose (13) to the blowing func-
tion connection port (9). Slide the end of the suction
hose (13) with the two nipples into the blowing func-
tion connection port (9).
• Insert the two nipples into the recesses. In the end
position, turn the suction hose (13) in a clockwise
direction.
Mounting the hose (13), aluminum tube (16) and flat
nozzle (17) (fig. H)
• Push the aluminum tube (16) or the flat nozzle (17)
onto the end of the suction hose (13).
8. Operation
m ATTENTION!
Before use, check all connections and the HEPA
filter (14) for a firm and secure connection. The
stainless steel container (6) and the HEPA filter (14)
must be absolutely dry.