Installation and connection

5
C ontents of package
I n s t a l l a t i o n a n d c o n n e c t i o n
After unpacking all parts, check for any damage in
transit.
If you have any complaints, contact the dealer from
whom you purchased the appliance or our after-sales
service.
"Customer service" on page 48
~
The delivery consists of the following parts:
Built-in appliance
Interior fittings (depending on model)
Installation material
User manual
Installation instructions
Customer service booklet
Warranty enclosure
Information on the energy consumption and noises

Technical specifications

Refrigerant, cubic capacity and further technical
specifications can be found on the rating plate.
"Getting to know your appliance" on page 32
~

Installing the appliance

Installation location
The more refrigerant an appliance contains, the larger
the room must be in which the appliance is situated.
Leaking refrigerant can form a flammable gas-air mixture
in rooms which are too small.
The room must be at least 1 m³ per 8 g of refrigerant.
The amount of refrigerant in your appliance is indicated
on the rating plate inside the appliance.
"Getting to know your appliance" on page 32
~
The weight of the appliance may be up to 70 kg
depending on the model.
Installation and connection
Permitted room temperature
The permitted room temperature depends on the
climatic class of the appliance.
Information on the climatic class can be found on the
rating plate.
"Getting to know your appliance" on page 32
~
Climatic
Permitted room
category
temperature
SN
+10 °C ... 32 °C
N
+16 °C ... 32 °C
ST
+16 °C ... 38 °C
T
+16 °C ... 43 °C
The appliance is fully functional within the permitted
room temperature.
If an appliance of climatic class SN is operated at
colder room temperatures, the appliance will not be
damaged up to a room temperature of +5 °C.

Cavity depth

A cavity depth of 56 cm is recommended
for the appliance. If the cavity depth is smaller – at least
55 cm – the energy consumption increases slightly.

Side by-side installation

It is only possible to install appliances side by side with
a gap of at least 15 cm.