Télécharger Imprimer la page

Jotul PF 923 S Manuel D'installation, D'utilisation Et D'entretien page 19

Publicité

SCHÉMA DE BRANCHEMENT ÉLECTRIQUE
R
20
2a
° t
R
24
UI/PC
ext 5-6
+
1
6
V
PWM
C01
RXT
DATA CABLE
CN12
C
L
220÷240Vac
r
8
PLUG C/FUSE 4 A
PE L
N
220-240Vac
NOTE:phase protection,added by customer.Do not change polarity!
32
1 CAPTEUR DE HALL
THERMOSTAT
2a
VENTILATEUR
DROITE
3 SONDE AMBIANT
4 SONDE GRANULÉS
5 SONDE DES FUMÉES
DIFFÉRENTIEL DE
6
PRESSION
36
JØTUL PF 923 S
1
3
6
4
K
° t
L
ext 1-2
POSITIVE
0 I
4
G
N
D
F
0
1
G
N
D
F
0
3
F
0
2
+
5
V
0 I
3
G
N
D
T
0
5
T
0
1
T
0
2
T
0
3
T
0
4
C
N
5
C
N
7
C
N
6
N
3
C
N
1
C
N
9
C
N
1
0
N
O
0
1
O
0
2
O
0
3
O
0
4
I01
0 I
2
O
16
air R
air
comb
Pa
12
9
14
10
11a
150 mm
RÉSISTANCE À
7
16 INDUCTANCE
INCANDESCENCE
EXTRACTEUR DES
18 VENTILATEUR
air R
8
FUMÉES
DOSEUR
UI /
10
24
CHARGEMENT
PC
11 SÉCURITÉ STB
12 SÉCURITÉ PRESSION
BASSE
VENTILATEUR
air
14
AMBIANT*
*Puissance thermique globale (rendement)
Rendement
Pa-
Pa+
Température fumées
Débit de fumée
Consommation horaire
Emission de CO (13% O
C
N
2
Évacuation fumées
K7
O06
O07
0
5
Prise d'air
Poids
Combustible
Capacité réservoir d'alimentation
Tirage
18
Pour calculer les dimensions du conduit de fumeé utilisez :
Foyer indiqué pour des volumes non inférieurs à
004725254 14/02/2022
Tension
AMBIANT DE DROITE
Fréquence
TABLEAU DE
COMMANDE
Puissance maximum absorbée en fonctionnement
Allumage électrique
CARACTÉRISTIQUES TECHNIQUES
JØTUL PF 923 S
(conforme à la norme EN 14785)
404,2 mg/Nm
)
2
STANDARDS ÉLECTRIQUES
Min
Max
2,2 kW
9,1 kW
94,33 %
91,77 %
65,1 °C
159,5 °C
2,7 g/s
5,3 g/s
0,477 kg/h
2,023 kg/h
47,2 mg/Nm
3
3
Ø 8 cm
Ø 6 cm
120 kg
Pellets
19 kg
12(±2) Pa
0.0 Pa
20 m
3
230 V
50 Hz
110 W
400 W
37

Publicité

loading