INSTALLATION MANUAL
CAA480A
Elevator Controller
To use both switches:
• Connect one end of the supplied wire, the one with
a log at each end, to the door tamper switch
terminal and the other end to the wall tamper switch
terminal.
• Connect the other terminal of the door tamper
switch to one of the "TAMPER" terminal using the
supplied wire.
• Connect the other terminal of the wall tamper
switch to the other "TAMPER" terminals using the
supplied wire.
To use only one switch:
• Connect one terminal of the tamper switch to one
of the "TAMPER" terminal using the supplied wire.
• Connect the other terminal of the same tamper
switch to the other "TAMPER" terminals using the
supplied wire.
!
!
If you are not using a tamper switch be sure to short the tamper inputs by connecting a wire between
the two "TAMPER" terminals.
5] CONNECTING AC POWER
A 15A AC power source with a dedicated breaker and an isolated ground is recommended.
Connect a 16VAC, 40VA (Maximun) transformer to the CAA480A's "AC" terminals
and mount it near the cabinet. Refer to Figure 3.
Figure 3: Connecting AC Power
!
!
Do not power up the CAA480A Elevator Controller until all connections and the CAA480A
settings are completed.
6
cdvigroup.com
AC
AC
BAT+
BAT-
+12V
+12V
GND
AC Supply
LED Indicator
GND
FC
FC
CAA480A
Elevator Controller
Figure 2c: Connecting Tamper Switches
CAA480A
E-BUS
ELEVATOR
CONTROLLER
A+
B-
GND
TAMPER
TAMPER
Transformer 16VAC-40VA
(Europe: CDVI TR1640 recommended)
(UL/ULC: CDVI150 or CDVI200 recommended)
CD VI
TR1 6/40
Installation must comply with
local codes and ordinances.
EN
DOOR
TAMPER
SWITCH
WALL
TAMPER
SWITCH