INSTALLATION MANUAL
CAA480A
Elevator Controller
Figure 18: CAA480A's LEDs:
Green "+12V RELAY" LED: (ON) Floor
control relays are receiving required
12VDC to operate.
Green "BATT" LED: (ON) backup
battery detected.
Red "RX" LED: Flashes
whenever receiving data
through the E-BUS.
E-BUS
RX TX
Red "TX" LED: Flashes
whenever the CAA480A
is transmitting data
through the E-BUS.
Green "STATUS" LED: (Flashing)
Firmware is running smoothly.
Future Use
17] DESTINATION REPORTING MODULE (DRM)
Normally, when a user presents their access card to the reader in the elevator car,
the CAA480A will activate and allow access to all the floors that the user is allowed to.
Though the controller will register the event, if the user has access to more than one
floor, you won't know which floor the user has accessed. With the Destination Reporting
Module (DRM - sold separately), the controller can register the user who accessed
the elevator and which floor was accessed, thus supplying an effective floor trace for each
card holder. Destination Reporting is also known as One Card, One Floor operation
as it only allows one floor selection to be made per presentation of the card.
AC
BATT REVERSED
12V
+12V RELAY
BATT
E-BUS
A+
A
LOW HIGH
B-
B
GND
LOW HIGH
TAMPER
EOL
TAMPER
COM1
E-BUS
NO1
RX TX
NC1
COM2
NO2
NC2
COM3
NO3
NC3
COM4
STATUS
NO4
FREE ACCESS
COMM FAILURE
NC4
BATT TROUBLE
CAA480A
RL5
RL6
RL7
RL8
RL9
STATUS
FREE ACCESS
COMM FAILURE
BATT TROUBLE
Green "AC" LED: (ON) AC power
is present.
Red "BATT REVERSED" LED: (ON)
Backup battery is hooked up in reverse
Green "12V" LED: (ON) CAA480A
panel is receiving the 12VDC required
to operate.
AC
AC
BAT+
BAT-
+12V
+12V
GND
AC
GND
BATT REVERSED
12V
FC
+12V RELAY
FC
BATT
NC16
NO16
COM16
NC15
NO15
COM15
NC14
ADRESS 1
ADRESS 2
NO14
ADRESS 4
ADRESS 8
COM14
RLY COMMS
RLY OFF/ON
NC13
DRM ENABLED
PWR OFF/ON
NO13
RL10
RL11
RL12
COM13
Green "FLOOR RELAY" LED: (ON)
Floor control relay is activated.
All 16 floor control relays have an LED.
Red "COMM FAILURE" LED: (ON)
The CAA480A has lost communication
with the CTV900A Controller.
Red "BATT TROUBLE" LED: (ON)
The backup battery has dropped
to 10.5VDC or lower.