INSTALLATION MANUAL
CAA480A
Elevator Controller
Outputs:
Relay Outputs: 16 Relay Outputs:
Inputs:
Emergency Alarm Inputs:
Controller Tamper:
Communication:
Expansion Bus (E-BUS):
Miscellaneous:
Operating Temperature:
Specifications may change without prior notice.
!
!
Installation must comply with local codes and ordinances.
3] LOCATION AND INSTALLATION
The CAA480A Elevator Controller comes as a printed circuit board (PCB) only or with a
cabinet. The cabinet is designed to allow easy and simple installation of floor control wiring,
the backup battery and interface connections. The ideal location to install your CAA480A is
as close to the elevator control system as possible. This will aid the elevator company by
limiting the amount of wire needed to connect each floor that is controlled by the CAA480A.
!
!
Please note that other approved cabinet with approved tamper switch on the front cover and
rear surface can be use.
• Cabinet Dimensions:
40 cm (15.8") high, 32 cm (12.6") wide, 9 cm (3.54") deep
• The cabinet can accommodate:
Up to two 12V, 7Ah, gel cell type batteries and wiring connections.
15cm (6") high x 6cm (2.5") wide x 10cm (4") deep.
• Multiple Conduit Knock-outs:
Two 19.05mm (0.75") on each side and one 12.7mm (0.5") on top.
• Minimum Clearance for Cabinet:
25cm (10") clear space around all sides.
38cm (15") clear space in front of cabinet.
• Minimum Clearance from Electrical Interference:
2.4m (8ft.) from high voltage equipment wiring and from electrical equipment likely
to generate interference.
1.2m (4ft.) from telephone equipment or lines and 8m (25ft.) from transmitting
equipment.
4
cdvigroup.com
15A (tested for compliance at 10A) @ 16VDC
(resistive load)
1 N.C.
1 N.C.
RS-485, Plug and Play
0°C to 49°C (32°F to 120°F)
EN