INSTALLATION MANUAL
CAA480A
Elevator Controller
BASIC OPERATION
The DRM has 16 Floor Selection Inputs (one for each floor control relay of the CAA480A).
A person presenting their card will be allowed to select a floor that they have access to.
Pressing one of the connected elevator floor buttons will only activate the floor control
relay corresponding to the selected floor thus allowing access to the desired floor. The
event will be logged through the controller as an "Access granted valid floor selection"
with the floor that was selected. In the case of a floor being selected that the user does
not have access to, the event "Invalid Floor Selection" will be generated and the user will
need to present their card again and then select another floor. In all cases, once a card is
presented, the user can only select one floor. Once the floor is selected (by pressing the
desired elevator floor button), the user must present their card again in order to select
another floor even if the floor selected was an incorrect one.
MOUNTING THE DRM ON TO THE CAA480A
The DRM connects directly to the CAA480A's DRM Module header plug using a 14-pin
cable. The DRM is designed to be mounted on plastic standoffs (supplied with the DRM)
and fastened to the CAA480A using 4 screws. The DRM comes with 16 floor selection
inputs, one for each floor control relay on the CAA480A. Before connecting the DRM make
sure that DIP switches 7 (DRM ENABLED) and 8 (PWR OFF/ON) are in the "ON" position.
Refer to Figure 19 for more details:
Figure 19: Mounting the DRM
Nylon Screws
(x4)
DRM
(CAA482P)
Plastic
A+
B-
Standoffs
GND
TAMPER
(x4)
TAMPER
COM1
NO1
NC1
COM2
NO2
NC2
COM3
NO3
NC3
COM4
NO4
NC4
!
!
Disconnect AC and battery power before mounting the DRM to the CAA480A.
22
cdvigroup.com
Elevator Controller
BAT+
BAT-
+12V
+12V
GND
GND
AC
BATT REVERSED
12V
FC
+12V RELAY
BATT
FC
NC 1
NO 1
COM 1
STATUS
NC 1
FREE ACCESS
BATT TEMPER
NO 1
BATT TEMPER
BATT TEMPER
COM 1
NC 1
NO 1
COM 1
NC 1
NO 1
COM 13
14-pin Flat
Cable
CAA480A
AC
AC
Before connecting the DRM to the CAA480A, DIP
switches 7 (DRM ENABLED) and 8 (PWR OFF/ON)
from the CAA480A must be in the "ON" position.
ADRESS 1
ADRESS 2
ADRESS 4
ADRESS 8
RLY COMMS
RLY OFF/ON
DRM ENABLED
PWR OFF/ON
EN