Système d'eau potable à osmose inverse
Installation - Drain Connection
Drain Connection
You will need an electric drill with a 3/8" (9.5mm) bit and a screwdriver for this portion of the installation.
Note: The drain saddle assembly must be installed before the P trap. Do not install the drain saddle
assembly after the P trap.
1. Obtain the drain saddle assembly with two 1 1/4"
(38mm) bolts, two 3/8" (9.5mm) hex nuts, and the
small adhesive foam pad from the small parts bag.
2. Place the adhesive foam pad on the inside of the
drain saddle front, aligning the holes.
3. Position the drain saddle on the drain pipe
under the sink between the P trap and the sink
connection. Orient the drain saddle so that the
opening is on the side of the drain pipe.
4. Using the bolts and hex nuts, hand-tighten the
saddle bracket evenly until the saddle grips the
pipe snugly. Use a Phillips screwdriver to fully
tighten the bolts. Do not over tighten.
5. If necessary, remove the drain saddle connector
nut from the opening of the drain saddle. Using
the connector opening in the side of the drain saddle as a guide, drill a 3/8" (9.5mm) hole through
the side wall of the drain pipe. Do not drill the hole on the top of the pipe.
6. Extend the drain tubing from the dispensing faucet to the drain saddle and measure for length. The
tubing must be routed so that water can run downhill for the entire length of the tubing from the
faucet. Avoid low spots or loops. Cut the tubing shorter, if necessary.
7. Insert the black drain tubing from the dispensing faucet through the drain saddle connector nut.
Tighten the connector nut onto the drain saddle.
Installation - System Activation and Flushing
System Activation and Inspection
1. Check all tubing connections to ensure they are firmly seated. CHECK TO SEE THAT THE CARTRIDGE
RETAINER CLIP IS PROPERLY ENGAGED AND LOCKED. FAILURE TO KEEP THE RETAINING CLIP
IN PLACE WILL RESULT IN ACCIDENTAL LEAKS AND FLOODING.
2. Open the dispensing faucet at the sink. Close the tank shutoff valve. Make sure the angle stop valve
for the incoming water is open. Open the small feed shutoff valve on feed valve assembly.
3. Observe all tubing and connections for several minutes to detect any leaks. In approximately 5
minutes, (assuming normal feed water pressure) the dispensing faucet should begin dripping.
4. Allow the faucet to run for up to 15 minutes, then close the faucet.
5. Check for leaks at all connections.
6. Open the tank shutoff valve.
7