Système d'eau potable à osmose inverse
Maintenance
Maintenance - Main Cartridge Replacement
1. Close the small shutoff valve on the feed valve assembly.
2. Close the tank shutoff valve.
3. Open the dispensing faucet to relieve system pressure. Close dispensing faucet when flow has
stopped.
4. Remove the cover from the front of the system. Remove the retaining clip. Pull the cartridge off the
system evenly at top and bottom. Dispose of used cartridge.
5. Install the new cartridge, rocking gently from side to side as necessary until the cartridge tubes are
properly engaged in the unit connectors. Install the retaining clip, ensuring the slide locks snap into
place in the slots. If the clip does not snap easily into place through the slots, it means the cartridge is
not fully inserted into the connectors. Press the top or bottom of the cartridge to engage the connector
so that it snaps fully into place. Failure to properly install the retaining clip will result in accidental
leaks and flooding.
6. Open the small shutoff valve on the feed valve assembly. Open the dispensing faucet.
7. Close dispensing faucet after water starts running.
8. Observe system for any leaks, especially at newly re placed cartridge.
9. Open the tank shutoff valve.
10. The system should be flushed at least once as described in System Activation and Flushing.