Maintenance - Postfilter Replacement
Postfilter Replacement
1. Close the small shutoff valve on the feed valve assembly.
2. Close the tank shutoff valve.
3. Open the dispensing faucet.
4. Close the dispensing faucet when the water stops flowing.
5. Locate the in-line filter on the faucet line.
6. Remove the tubing by depressing the collet toward the filter and pulling the blue tubing from the filter.
7. Remove the other side of the blue tubing as described above.
8. Reverse the above steps to install the new in-line filter, making sure that the tubing is pressed in as
far as possible.
9. Open the small shutoff valve on the feed valve assembly. Observe system for any leaks, especially
at newly re placed cartridge.
10. Open the tank shutoff valve.
11. The system should be flushed at least once as described in System Activation and Flushing.
10