17. Troubleshooting
Failure
Possible cause
Motor does not start
• Fastening nut tightened insufficiently
• Extension cable defect
• Connections on the motor or switch
defect
• Motor or switch defect
• Capacitor defect
Motor runs forward or
backwards
No motor output turns
• Overload by dull saw
off automatically
• Wrong saw blade
Burns on the cutting
• Fastening nut tightened insufficiently
surface
• Wrong saw blade
Saw band clamps
• Saw band blunt
when working
• Saw band resinified
• Leadership poorly adjusted
 www.scheppach.com /  service@scheppach.com /  +(49)-08223-4002-99 /  +(49)-08223-4002-58
Solution
• Check the mains fuse
• See "Electrical Connection" in the operating
• Have it checked by an electrician Brake does
not bleed
• See "Electrical Connection" in the operating
manual
• Have it exchanged by an electrician
• Insert a sharpened saw blade; motor can be
turned on again
• Select saw band according to instructions
• Insert a sharpened saw blade
• Select saw band according to instructions
• Replace saw band
• Clean saw band
• Saw band guidance according to instructions