Event E A9
SKIP ramp interrupted
If the controller failed to reach the end temperature in an uncontrolled ramp up it will
continue with the next segment. This message is displayed for one minute to inform
the user.
Event E B2 („E b2")
Firing process continued after power failure
The firing process continues after power failure if the temperature has not dropped by
more than 50 °C.
Event E B3 („E b3")
Firing process interrupted after power failure
After re-establishing power supply, the firing process has been interrupted because,
for example, the kiln temperature has dropped too much. A digit shown after the
comma will provide further information concerning the cause (e.g. B3.4 =
temperature dropped too much). If this message is displayed immediately after the
controller has been turned on, you may ignore it. This indicates that the controller was
turned off while the firing process and program were still operational. You can
continue by entering a program.
Event E B4 („E b4")
Controller ambient temperature too high
The ambient temperature of the controller has exceeded 55 °C. Check room
ventilation, the controller is possibly too far away from the kiln.
Event E B5 („E b5")
Heating gradient below half of new value
The maximum heating gradient of the kiln has fallen below half of the new value. Firing
is not interrupted. This error message can indicate that the heating elements are
almost worn out.