Display during a firing
By default, the green display indicates the actu-
al setpoint temperature during a firing . When
heating up, this setpoint temperature "counts
upwards" according to the rate set .
The end temperature of the selected firing curve
flashes up on the display twice every 15 se-
conds . This allows you to check this important
value without pushing any keys .
You can observe the firing curve to see how your
TC 504 processes it segment by segment .
When the kiln temperature has reached 150°C
during cooling down, the program is complete .
The green display reads "End" confirming that
the firing process has been completed success-
fully .
On most firings the customer wants to heat up
the kiln as quickly as possible from 2nd dwell
temperature to end temperature . You can do this
by entering the value "SKIP" .
Select the respective segment .
Enter a value larger than 998°C/h in order to get
"SKIP" .
We do not recommend that you use "SKIP"
for glaze firings in kilns with large firing
chambers.