Safety distances from non-combustible materials:
Back (dR)
Side (dS)
7.2 Combustion air
The required oxygen for the fire is supplied through the lower backside of the stove.
An optimal combustion requires sufficient fresh air. A lack of oxygen may result in incomplete combustion
and reversing flue gases.
ATTENTION!
Extractor fans when operating in the same room or space as the appliance may cause problems.
Additional combustion air can be supplied by placing an air inlet grill as close as possible to the appliance.
Air inlet grills must be positioned so that they are not liable to blockage.
Fresh air supply enables the additional deliverable outdoor air connection to come into force. Remove the
rupture disc on the back of the coat. Place and install the outdoor air connection under the fireplace by
using non-combustible drainage materials with a diameter of 80 mm.
50
200 mm
300 mm