7 I
NSTALLATION
All local regulations, including those referring to national and European standards need to be complied with
when installing the appliance.
Only an appliance connected by a qualified installer guarantees compliance with legislation on construction
and fire prevention. This is certainly required for safe and proper use of the stove.
7.1 Positioning
The appliance shall be erected on floors with an adequate loadbearing capacity (see technical data). If an
existing construction doesn't meet this prerequisite, suitable measures shall be taken to achieve it.
Adjust if necessary the feet of the appliance to position it at level.
If the stove is installed on an inflammable floor, then place a fireproof plate underneath the appliance. Safety
clearance distances from combustible materials:
Back (dR)
Front (dP)
Front to the floor (dF)
Side (dS)
Side with glass (dS1)
Side - niche (dS2)
Side - location 45° (dS3)
Side - radiation (dL)
From the floor (dB)
From the ceiling (dC)
300 mm
1200 mm
450 mm
300 mm
300 mm
100 mm
100 mm
430 mm
10 mm
750 mm