1. Operating instructions
1.1 Introduction
Dear Customer,
DIVA D C24 is a high-efficiency heat generator for heating and domestic hot water production, running on Natural Gas
or LPG and equipped with a microprocessor control system.
1.2 Control panel
Panel
4
5
3
14
13
11
fig. 1- Control panel
Indication during operation
Heating
A heating demand (generated by the Room Thermostat or Remote Timer Control) is indicated by the symbol 13 flashing
on the display.
The display (detail 11 - fig. 1) shows the actual heating flow temperature and, during heating standby time, the message
"d2".
In case of continuous messages "d2" reduce the parameter P01 (ignition power - See table 3) to a minimum of 9.
DHW (domestic hot water)
A DHW demand (generated by drawing hot water) is indicated by the symbol 9 flashing on the display.
The display (detail 11 - fig. 1) shows the actual DHW outlet temperature and, during DHW standby time, the message
"d1".
32
7
2
6
16
1
10
15
9
8
12
cod. 3542B920 - Rev 07 - 06/2024
DIVA D C24
Panel legend fig. 1
1
DHW temperature setting decrease button
2
DHW temperature setting increase button
3
Heating system temperature setting decrease
button
4
Heating system temperature setting increase
button
5
Display
6
"Sliding Temperature" Menu - Summer/Winter
mode selection - Reset button
7
Unit On/Off - Economy/Comfort mode selection
button
8
DHW symbol
9
DHW mode
10
Summer mode
11
Multifunction
12
Eco (Economy) mode
13
Heating
14
Heating symbol
15
Burner lit and actual power level.
16
Service Tool connection
EN